ZR-KYJVP2-23交聯(lián)聚乙烯絕緣聚乙烯護套銅帶屏蔽鋼帶鎧裝阻燃控制電纜
- 添加時(shí)間:2022-02-17 10:12:26
- 瀏覽:
Description
執行標準Executive standard
本產(chǎn)品按照GB/9330、GB/T19666標準生產(chǎn)制造。
This product is manufactured in accordance with GB/9330 and GB/T19666 standards.
需要時(shí),阻燃試驗要求符合GB/T18380(IEC60332)的規定。
When necessary, the flame retardant test requirements shall meet the requirements of GB/T18380 (IEC60332).
需要時(shí),耐火試驗要求符合GB/R19216(IEC60331)的規定。
When necessary, the fire resistance test requirements shall meet the requirements of GB/R19216 (IEC60331).
需要時(shí),燃燒性能等級(A、B1、B2、B3)符合GB31247的規定。
When necessary, the combustion performance level (A, B1, B2, B3) meets the requirements of GB31247.
需要時(shí),火焰蔓延、熱釋放和產(chǎn)煙特性試驗要求符合GB/T31248的規定。
When necessary, the flame spread, heat release and smoke generation characteristics test requirements meet the requirements of GB/T31248.
適用范圍Scope of application
本產(chǎn)品適用于交流額定電壓(U0/U)450/750V及一次啊的電器儀表、配電裝置的信號傳輸、控制和測量系統?蓮V泛應用于冶金、電力、石油、化工等各種領(lǐng)域。
This product is suitable for the signal transmission, control and measurement system of electrical instruments and power distribution devices with AC rated voltage (U0/U) 450/750V and one-time. It can be widely used in various fields such as metallurgy, electric power, petroleum and chemical industry.
使用特性Use characteristics
1、電纜額定電壓U0/U:450/750V
Rated cable voltage U0/U: 450/750V
U0-電纜設計用的導體對地域金屬屏蔽之間的額定工頻電壓;
U0-The rated power frequency voltage between the conductor used in the cable design and the regional metal shield
U-電纜設計用的導體間的額定工頻電壓;
U- rated power frequency voltage between conductors used in cable design;
2、電纜正常運行時(shí)導體很高工作溫度:交聯(lián)聚乙烯絕緣為90℃;聚氯乙烯絕緣為70℃。
The maximum working temperature of the conductor during the normal operation of the cable: 90°C for cross-linked polyethylene insulation; 70°C for polyvinyl chloride insulation.
3、電纜短路時(shí)導體很高溫度:交聯(lián)聚乙烯絕緣為250℃;聚氯乙烯絕緣為160℃(短路很長(cháng)持續時(shí)間為5秒)。
The maximum temperature of the conductor when the cable is short-circuited: 250°C for cross-linked polyethylene insulation; 160°C for polyvinyl chloride insulation (the longest short-circuit duration is 5 seconds).
4、電纜安裝時(shí)很小彎曲半徑:
Minimum bending radius during cable installation:
有鎧裝或繞包屏蔽結構的電纜應不小于電纜外徑的12倍;
Cables with armored or wrapped shielding structure should not be less than 12 times the outer diameter of the cable;
其余結構電纜應不小于電纜外徑的6倍。
Other structural cables should not be less than 6 times the outer diameter of the cable.
5、電纜的很低允許敷設溫度:敷設時(shí)電纜溫度不低于0℃,環(huán)境溫度低于0℃時(shí),應對電纜進(jìn)行預熱。
The minimum allowable laying temperature of the cable: the temperature of the cable shall not be lower than 0℃ during laying, and the cable should be preheated when the ambient temperature is lower than 0℃.
6、電纜絕緣電阻:很高額定溫度時(shí)。體積電阻率r不低于1012Ω.cm;絕緣電阻常數Ki不小于36.7MΩ.km。Cable insulation resistance: at the highest rated temperature. The volume resistivity r is not less than 1012Ω.cm; the insulation resistance constant Ki is not less than 36.7MΩ.km.
主要實(shí)驗項目及指標Main experimental items and indicators
1、20℃時(shí)導電線(xiàn)芯很大直流電阻
Maximum DC resistance of conductive core at 20℃
規格 Specification | 20℃時(shí)導體很大直流電阻 Maximum DC resistance of conductor at 20℃ | ||
第1種導體 First conductor | 第二種導體 Second conductor | 第五種導體 The fifth conductor | |
0.5 | 36.0 | 36.0 | 39.0 |
0.75 | 24.5 | 24.5 | 26.0 |
1.0 | 18.1 | 18.1 | 19.5 |
1.5 | 12.1 | 12.1 | 13.3 |
2.5 | 7.41 | 7.41 | 7.98 |
4 | 4.61 | 4.61 | 4.95 |
6 | 3.08 | 3.08 | 3.30 |
10 | 1.83 | 1.83 | 1.91 |
2、交流電壓試驗:A.C voltage test
額定電壓450/750V成品電纜應能經(jīng)受工頻3000V電壓試驗5min不擊穿。
The finished cable with rated voltage of 450/750V should be able to withstand the power frequency 3000V voltage test for 5 minutes without breakdown.
電纜結構圖Cable Drawing
1.導體conductor
2.交聯(lián)聚乙烯絕緣XLPE insulation
3.聚酯帶Polyester tape
4.銅帶繞包屏蔽Copper tape wrapped shield
5.內襯層Inner lining
6.鎧裝層Armor layer
7.護套層Sheath